Active emollient with maintenance of reenergizing of a key at a zero voltage

Authors

  • R. V. Antypenko National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev https://orcid.org/0000-0002-8931-1977
  • I. M. Kyrpatenko National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev
  • I. O. Kukhartchuk National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev
  • A. V. Movchanyuk National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev https://orcid.org/0000-0003-2901-0424
  • V. P. Fesich National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev

DOI:

https://doi.org/10.20535/RADAP.2008.37.164-167

Keywords:

активний демпфер, джерела електроживлення

Abstract

A new circuit of active emollient, which provides zero voltage switching conditions are presented.

Author Biographies

  • R. V. Antypenko, National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev

    Antypenko R. V., Cand. of Sci (Techn), Assoc. Prof.

  • I. M. Kyrpatenko, National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev
    Кирпатенко І.М., к.т.н., доцент кафедри радіоприймання та оброблення сигналів
  • I. O. Kukhartchuk, National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev
    Кухарчук І.О., студент радіотехнічного факультету
  • A. V. Movchanyuk, National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev

    Ph.D., Associate Professor

  • V. P. Fesich, National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev
    Фесіч В.П., інженер кафедри радіоприймання та оброблення сигналів

References

Лукин А. В., Кастров М.Ю., Малышков Г. М., и др. Преобразователи напряжения силовой электроники. – М.: Радио и связь, 2004. – с. 415.

Четти П. Проектирование ключевых источников электропитания: Пер.с англ. М.: Энергоатомиздат, 1990. с.240.

Designing for High Efficiency with the Active Clamp UCC2891 PWM Controller.Texas Instruments. Application report. April – 2004.

БраунМ. Источники питания. Расчет и конструирование. К.:«МК - Прес», 2005. 288 с.

Solving noise problems in high power, high frequency control IC driven power stages. Control Integr.circuit designers manual. Inter. Rectifier. El Segundo, California. 1996.

Maximizing the latch immunity of the IR2151 and IR2152 in ballast applications. Control Integr.circuit designers manual. Inter. Rectifier. El Segundo, California. 1996.-

Issue

Section

Information about completed design

How to Cite

“Active emollient with maintenance of reenergizing of a key at a zero voltage” (2008) Visnyk NTUU KPI Seriia - Radiotekhnika Radioaparatobuduvannia, (37), pp. 164–167. doi:10.20535/RADAP.2008.37.164-167.

Most read articles by the same author(s)

1 2 > >>