Comparative analysis of promising current sources for electrical impedance tomography in an extended frequency range

Authors

  • G. V. Timoshenko National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev
  • E. V. Gaydayenko National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev http://orcid.org/0000-0001-8660-5067

DOI:

https://doi.org/10.20535/RADAP.2012.51.115-121

Keywords:

impedance tomography, current source, complex resistance, Howland circuit, phase shift, the active feedback

Abstract

Iintroduction: Features of biological impedance meters are listed and requirements for their current sources are formed. Formulation of the problem: A review of existing current sources and puts forward proposals to explore the parameters of some of them and the current source on a fully integrated differential amplifier with active feedback. Methods of research and analysis of the results: Describes the method of measuring the parameters of current sources, critically reviewed the results and recommendations for the use of these sources. Conclusion: The accomplishments and weaknesses of the investigated sources, given ways to improve their parameters are considered.

Author Biographies

G. V. Timoshenko, National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev

M.S., Postgraduate Student

E. V. Gaydayenko, National Technical University of Ukraine, Kyiv Politechnic Institute, Kiev

M.S., Postgraduate Student

References

Література

Electrical Impedance Tomography: Methods, History and Applications [Електронний ресурс] – режим доступу: http://67.227.185.184/docs/pubs/Part_1_of_Electrical_Impedance_Tomography_Methods_History_and_Applications.pdf. – Назва з екрана.

Yang W. Tomographic Imaging based on Capacitance Measurement and Industrial Applications / Yang W. //IEEE International Workshop on Imaging on Systems and Techniques. – 2007. – P. 1–6.

Griffiths H. A dual frequency electrical impedance tomography system / Griffiths H., Zhang Z. // Phys. Med. Biol. – 1989. – V. 34. – № 10. – P. 1465 –1476.

Wang W. A Comprehensive Study on Current Source Circuits / ICEBI 17. – 2007. – P. 213-216.

Хоровиц П. Искусство схемотехники: В 3-х томах. / Хоровиц П., Хилл У., пер. С англ. Б.Н. Бронин и др. – [5-е изд, перераб]. – М.: Мир, 1998. – 418 с.

Franco S. Design with Operational Amplifiers and Analog Integrated Circuits / Franco S. – [3rd ed.]. – New York : McGraw-Hill, 2002. – 658 p.

Soleimani М. Electrical Impedance Tomography System / M. Soleimani. // BioMedical Engineeeing OnLine. – 2006. – №12. – P. 1 – 8.

Denyer C. W. Electronics for real-time and three-dimensional electrical impedance TOMOGRAPHs / C. W. Denyer. – A thesis submitted in partial fulfillment of the require-ments of Oxford Brookes University for the degree of Doctor of Philosophy. – 1996. – Jan-uary. – 132 p.

Bertemes-Filho P. A. Comparison of modified Howland circuits as current generators with current mirror type circuits. / P. Bertemes-Filho., B. H. Brown., A. J. Wilson. // Physiological measurements Journal. – 2000. – №21. – P. 1–6.

Boone K. G. Design in Electrical Impedance Tomography. / K. G. Boone, D. S. Holder. // Physiological measurements Journal. – 1996. – №17. – P. 229 –247.

Jossinec J. Active current electrodes for in vivo electrical impedance tomography. / J. Jossinec, C. Tourtel, R. Jany. // Physiological measurements Journal. – 1994. – №15. – P. 83 –90.

Фокин A. B. Источник тока для электроимпедансной томографи / A. B Фокин ., К. С. Бразовский // Известия Томского Политехнического Университета. – 2008. – Т.313 №4. – С. 99 –101.

Jossinet J. Assessment of electrical impedance endotomography for hardware specification / J. Jossinet, A. Fournier-Desseux, A. Matias. // Biomedical Imaging and Intervention Journal. – 2006. – March.

Сушко I. O. Потенційна чутливість імпедансної томографії / І. О. Сушко., Є.В. Гайдаєнко., О.А Якубенко // Вісник НТУУ "КПІ". Серія Радіотехніка, Радіоапаратобудування. – 2012. – №50. – С. 92 –104.

References

Electrical Impedance Tomography: Methods, History and Applications. http://67.227.185.184/docs/pubs/ Part_1_of_Electrical_Impedance_Tomography_Methods_History_and_Applications.pdf. — Nazva s ekrana.

Yang W. Tomographic Imaging based on Capacitance Measurement and Industrial Applications. IEEE International Workshop on Imaging on Systems and Techniques, 2007, pp. 1-6.

Griffiths H. A., Zhang Z. dual frequency electrical impedance tomography system. Phys. Med. Biol., 1989, vol. 34, no. 10, pp. 1465-1476.

Wang W. A Comprehensive Study on Current Source Circuits. ICEBI 17, 2007, pp. 213-216.

Horovits P., Hill U. Iskusstvo shemotehniki: V 3-h tomah, per. s angl. B. N. Bronin i dr. Moscow, Mir, 1998, 418 p.

Franco S. Design with Operational Amplifiers and Analog Integrated Circuits. New York, McGraw-Hill, 2002, 658 p.

Soleimani М. Electrical Impedance Tomography System. BioMedical Engineeeing OnLine, 2006, no. 12, pp. 1-8.

Denyer C. W. Electronics for real-time and three-dimensional electrical impedance TOMOGRAPHs.A thesis submitted in partial fulfillment of the requirements of Oxford Brookes University for the degree of Doctor of Philosophy, 1996, January, 132 p.

Bertemes-Filho P. A., Brown B.H., Wilson A.J. Comparison of modified Howland circuits as current generators with current mirror type circuits. Physiological measurements Journal, 2000, no. 21, pp. 1-6.

Boone, K.G., Holder D.S. Design in Electrical Impedance Tomography. Physiological measurements Journal, 1996, no. 17, pp. 229-247.

Jossinec J., Tourtel C., Jany R. Active current electrodes for in vivo electrical impedance tomography. Physiological measurements Journal, 1994, no. 15, pp. 83-90.

Fokin A.V., Brazovskij K.S. Istochnik toka dlya e'lektroimpedansnoj tomografii. Izvestiya Tomskogo Politehnicheskogo Universiteta, 2008, vol. 313, no. 4, pp. 99-101.

Jossinet J., Fournier-Desseux A., Matias A. Assessment of electrical impedance endotomography for hardware specification. Biomedical Imaging and Intervention Journal, 2006, March.

Sushko I. O., Haidaienko Ye. V., Yakubenko О. А. Potentsiina chuchutlyvist impedansnoi tomografii.

Visnyk NTUU "KPI". Serija Radiotehnika, Radioaparatobuduvannja, 2012, no. 50, pp. 92-104.

Published

2012-12-05

How to Cite

Тимошенко, Г. and Гайдаєнко, Є. (2012) “Comparative analysis of promising current sources for electrical impedance tomography in an extended frequency range”, Visnyk NTUU KPI Seriia - Radiotekhnika Radioaparatobuduvannia, 0(51), pp. 115-121. doi: 10.20535/RADAP.2012.51.115-121.