Dynamics of frequency dependences of parameters of electric impedance of a person during dry fasting

Authors

DOI:

https://doi.org/10.20535/RADAP.2017.70.43-48

Keywords:

functional state, electrical impedance parameters, bioimpedance, physiological changes, fasting

Abstract

Introduction The article considers the possibility of further development of the method of analysis of the parameters of electrical impedance to determine the current functional state of a person in various conditions of his life, in particular during the "dry" fasting.
The aim of the study was the dispersion properties investigation of the amplitude and phase parameters of human body impedance in the extended frequency band during the weekly one and half day "dry" fasting.
Methods. Measurement of electrical impedance parameters was performed weekly during half a year on one person before, during and after a day and a half fasting . Broadband three-frequency measurement technique is used. The possibility of analyzing the dispersion characteristics of a human body using the Cole hologram is considered.
Results and discussion. It is established that in the process of "dry" fasting there is a change of all parameters of impedance. The most pronounced changes in the parameters of electrical impedance are observed by the definition of the module and the active component at a frequency of 100 kHz, the phase at frequencies 20 and 500 kHz, the reactive component at a frequency of 20 kHz.
Conclusion. Changes in the dispersion properties of the human body impedance are noticeable in all parameters especially in phase and reactive resistance. According to the research results an interpretation of changes in the functional state of a person during fasting was made.

Author Biographies

O. B. Sharpan, National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute"

Sharpan O. B., Doc. of Sci(Tech), Prof.

V. S. Mosiychuk, National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute"

Mosiichuk V. S., Cand. of Sci(Tech), Assoc. Prof.

References

Перелік посилань

Cotter G. Accurate, noninvasive, continuons monitoring of cardiac output by whole-body electrical bioimpedance / G. Cotter, Y. Moshkowitz, E. Kalusky et al. // Chest. - 2004. - Vol. 125, No 4. - pp. 143-40.

Grimnes S. Bioimpedance and bioelectricity basics / S. Grimnes , O.G. Martinsen . Amsterdam: Elsevier, 2008. - 471 p.

Коtanko P. Curent state of bioimpedance technologies in dialiysis / P. Коtanko, W. Nathan, L.F. Zhu // J. Med. Nephrology Dialysis Transpl. - 2008. - Vol. 23, No 3. - pp. 808-812.

Gupta D. Bioelectrical impedance phase angle as a prognostic indicator in breast cancer / D. Gupta, C.A. Lammersfeld, P.G. Vashi // BMC Cancer. - 2008. - Iss. 8, pp. 249.

Николаев Д.В. Биоимпедансный анализ состава тела человека / Д.В. Николаев, А.В. Смирнов, И.Г. Бобринская, С.Г. Руднев. - М. : Наука, 2009. - 392 с.

Santarpia L. Prognostic significance of bioelectrical impedance phase angle in advanced cancer: preliminary observations / L. Santarpia, M. Marra, C. Montagnese et al. // Nutrition. - 2009. - Vol 25, No 9. - pp. 930–1.

Ярошенко В.Т. Варіанти біоімпедансометрії при вивченні вікової фізіології людини / В.Т. Ярошенко, О.Б. Шарпан // Наукові вісті НТУУ ``КПІ''. - 2009. - № 1. - с. 26-29.

Paterno A. Efficient Computational Techniques in Bioimpedance Spectroscopy / A. Paterno, L. H. Negri, P. Bertemes-Filho. - InTech, 2012. - рр. 4-28.

Colín-Ramírez E. Bioelectrical impedance phase angle as a prognostic marker in chronic heart failure / E. Colín-Ramírez, L. Castillo-Martínez, A. Orea-Tejeda // Nutrition. - 2012. - Vol. 28, No 9, pp. 901-5.

Рахматуллина Л.Н. Применение биоимпедансного монитора состава тела (BCM) в клинической практике у диализных больных (обзор литературы) / Л.Н.Рахматуллина, К.Я. Гуревич // Нефрология. - 2013. - Вып. 17, № 4. - 49-57.

Цейтлин Г.Я. Значение биоимпедансного анализа и антропометрии для прогнозирования осложнений у детей с онкологическими и неонкологическими заболеваниями после трансплантации гемопоэтических стволовых клеток / Г.Я. Цейтлин, А.Ю. Вашура, М.В. Коновалова, Д.Н. Балашов и др. // Онкогематология. - 2013. - Вып. 8, № 3. - с. 48-54.

Торнуев Ю. В. Диагностические возможности неинвазивной биоимпедансометрии / Ю. В. Торнуев, Д.Л. Непомнящих, Д.Б. Никитюк, Г.А. Лапий и др. // Фундаментальные исследования. - 2014. - № 10 (4). - с. 782-788/

Barni S. Detection of Allergen-IgE interaction in Allergic Children Through Combined Impedance and ROS Measurements / S. Barni, A. Fort, M. Becatti, C. Fiorillo and et al. // IEEE Transactions on Instrumentation and Measurement. - 2017. - Vol. 66, No. 4. - pp. 616-623.

Mosiychuk V. S. Bioimpedance Monitoring of Dialysis Patients During Ultrafiltration / V. S. Mosiychuk, G. V. Timoshenko, O. B. Sharpan, B. V. Tkachuk, R. S. Tomashevskyi //IEEE 36th International Conference on Electronics and Nanotechnology (ELNANO). - pp. 236-239.

Mosiychuk V. S. Wideband bioimpedance meter with the active electrodes / V. S. Mosiychuk, G. V. Timoshenko, O. B. Sharpan // IEEE 35th International Scientific Conference on Electronics and Nanotechnology (ELNANO). - pp. 300-303.

Самойлов В. О. Медицинская биофизика / В. О. Самойлов. - СПб. : СпецЛит, 2013. - 591 с.

Cole K. S. (1941). Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics / K. S. Cole, R. H. Cole // The Journal of Chemical Physics. - 1941. - Vol 9, No 4, pp. 341–351.

References

Cotter G., Moshkovitz Ya., Kaluski E., Cohen A. J., Miller H., Goor D. and Vered Z. (2004) Accurate, Noninvasive Continuous Monitoring of Cardiac Output by Whole-Body Electrical Bioimpedance. Chest Journal, Vol. 125, Is. 4, pp. 1431–1440. DOI: 10.1378/chest.125.4.1431

Grimnes S., Martinsen O.G. (2008) Bioimpedance and bioelectricity basics. Amsterdam: Elsevier, 471 p.

Коtanko P., Nathan W. and Zhu L.F. (2008) Curent state of bioimpedance technologies in dialiysis, J. Med. Nephrology Dialysis Transpl, Vol. 23, Is. 3, pp. 808-812. DOI: 10.1093/ndt/gfm889

Gupta D., Lammersfeld C.A., Vashi P.G., King J., Dahlk S.L., Grutsch J.F. and Lis C.G. (2008) Bioelectrical impedance phase angle as a prognostic indicator in breast cancer. BMC Cancer, 8:249. DOI: 10.1186/1471-2407-8-249

Nikolaev D.V., Smirnov A.V., Bobrinskaya I.G. and Rudnev S.G. (2009) Bioimpedansnyi analiz sostava tela cheloveka [Bioimpedance analysis of human body composition], Moskow, Nauka, 392 p.

Santarpia L., Marra M., Montagnese C., Alfonsi L., Pasanisi F. and Contaldo F. (2009) Prognostic significance of bioelectrical impedance phase angle in advanced cancer: preliminary observations. Nutrition, Vol. 25, No 9, pp. 930–1. DOI: 10.1016/j.nut.2009.01.015

Yaroshenko V.T. and Sharpan O.B. (2009) Bioimpedancometry Variants in Studies of Human Age Physiology, Naukovi visti NTUU ``KPI'', No 1, pp. 26-29. (in Ukrainian)

Paterno A., Negri L.H. and Bertemes-Filho P. (2012) Efficient Computational Techniques in Bioimpedance Spectroscopy, Applied Biological Engineering - Principles and Practice, Dr. Ganesh R. Naik (Ed.), InTech, DOI: 10.5772/36307.

Colín-Ramírez E., Castillo-Martínez L., Orea-Tejeda A., Vázquez-Durán M., Rodríguez A.E. and Keirns-Davis C. (2012) Bioelectrical impedance phase angle as a prognostic marker in chronic heart failure. Nutrition, Vol. 28, Is. 9, pp. 901-5. DOI: 10.1016/j.nut.2011.11.033

Rakhmatullina L.N. and Gurevich K.Y. (2013) Application bioimpedance body composition monitor (BCm) in clinical practice in dialysis patients (literature review), Nefrologiya, Vol. 17, No 4, pp. 49-57.

Tseytlin G.Y., Vashura A.Y., Konovalova M.V., Balashov D.N., Maschan1, M.A. and Belmer S.V. (2013) Value of bioimpedance analysis and anthropometry for complication prediction in children with malignant and non-malignant diseases after hematopoietic stem cells transplantation. Oncohematology. Vol. 8, Is. 3, pp. 48-54. DOI:10.17650/1818-8346-2013-8-3-48-54

Tornuev Y.V., Nepomnyaschikh D.L., Nikityuk D.B., Lapiy G.A., Molodykh O.P., Nepomnyaschikh R.D., Koldysheva E.V., Krinitsyna Y.M., Balakhnin S.M.,Manvelidze R.A., Semenov D.E., Churin B.V. (2014) Diagnostic capability of noninvasive bioimpedance. Fundamental Research, No. 10, pp. 782-788.

Barni S.,Fort A., Becatti M., Fiorillo C., Mugnaini M., Vignoli V., Addabbo T., Pucci N. and Novembre E. (2017) Detection of Allergen-IgE interaction in Allergic Children Through Combined Impedance and ROS Measurements, IEEE Transactions on Instrumentation and Measurement, Vol. 66, No. 4, pp. 616-623. DOI: 10.1109/tim.2016.2640478

Mosiychuk V. S., Timoshenko G. V., Sharpan O. B., Tkachuk B. V., Tomashevskyi R. S. (2016) Bioimpedance Monitoring of Dialysis Patients During Ultrafiltration, IEEE 36th International Conference on Electronics and Nanotechnology (ELNANO), pp. 236-239. DOI: 10.1109/elnano.2016.7493056

Mosiychuk V. S., Timoshenko G. V. and Sharpan O. B. (2015) Wideband bioimpedance meter with the active electrodes, IEEE 35th International Conference on Electronics and Nanotechnolog (ELNANO), pp. 300-303. DOI: 10.1109/elnano.2015.7146896

Samoilov V. O. (2013) Meditsinskaya biofizika [Medical Biophysics]. SPb, SpetsLit, 591 p.

Cole K. S. and Cole R. H. (1941) Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics, The Journal of Chemical Physics, Vol. 9, No 4, pp. 341–351. DOI: 10.1063/1.1750906

Published

2017-09-30

How to Cite

Шарпан, О. Б. and Мосійчук, В. С. (2017) “Dynamics of frequency dependences of parameters of electric impedance of a person during dry fasting”, Visnyk NTUU KPI Seriia - Radiotekhnika Radioaparatobuduvannia, 0(70), pp. 43-48. doi: 10.20535/RADAP.2017.70.43-48.

Issue

Section

Radioelectronics Medical Technologies